INDIGOiND Construction Solutions
Home/Site assessment forms/Swimming Pool / Sauna Waterproofing
Pre-job site assessment

Swimming Pool / Sauna Waterproofing

Site Assessment Form · Operation/Procedure  |  Rev 1.0
⚠ Confirm immersion & exposure conditions first  ·  Continuous immersion, chemicals & thermal cycling change the system selection
A

Project Basics

Project Name / Building Name
Project Location
Client / Company Name
Contact Person
Mobile / WhatsApp Number
Email ID
Type of Project
Is the Project New or Existing?
Expected Start Date
Work Shift
Is the Area Accessible During Working Hours?
B

Application Area & Usage

What Area Requires Waterproofing?Select all that apply
What Type of Pool Is This?
Pool Location
Is the Pool Indoor or Outdoor?
Is the Sauna / Steam Area Indoor or Outdoor?
How Will the Area Be Finished?
Will the Waterproofing Be Covered After Application?
ℹ Waterproofing under finishes Swimming pools and wet areas are normally waterproofed beneath the final tile, stone or other finish. The system therefore needs to be compatible with the adhesive, screed and finishing system installed above it.
C

Pool / Sauna Dimensions

Pool Length / Width / Depth
Approximate Waterproofing Area
Approximate Vertical Wall Area
Approximate Floor Area
Approximate Number of Corners / Steps
Number of Skimmers / Overflow Points
Number of Drains
Number of Pipe Penetrations
Sauna / Steam Room Area
Sauna / Steam Room Height
Approximate Wall / Ceiling AreaOr "Not Known"
D

Existing Substrate & Condition

What Is the Existing Substrate?
Condition of Existing Substrate
Is the Structure New or Existing?
Are There Visible Cracks?
Are There Structural Cracks?
Are There Construction / Expansion Joints?
Is There Existing Waterproofing?
If Yes, What System Was Used?
Is Existing Tile / Finish Present?
Is Removal of Existing Tile Required?
Is Hacking / Removal of Existing Waterproofing Required?
Are There Areas of Honeycombing / Voids?
Are There Damp / Wet Areas?
ℹ Substrate condition Waterproofing performance depends heavily on the substrate beneath the system. Cracks, honeycombing, weak concrete, movement joints and poorly prepared surfaces must be identified and treated before the waterproofing system is installed.
E

Water & Exposure Conditions

Will the Structure Hold Water Continuously?Drives system selection — permanent immersion vs standard wet-area
Is Hydrostatic Pressure Expected?
Is the Pool Exposed to Groundwater?
Is the Pool Below Ground Level?
Is the Pool Exposed to Direct Sunlight?
Is the Area Exposed to Rain?
Will Chlorinated / Treated Water Be Used?
Will Salt Water / Salt Chlorination Be Used?
Will Chemicals Be Used for Water Treatment?
ℹ Immersion conditions A swimming pool waterproofing system remains exposed to water pressure and, depending on the pool, continuous immersion and water-treatment chemicals. The system must be selected for permanent wet service, not treated as ordinary bathroom waterproofing.
F

Sauna / Steam Room Requirements

Is This a Sauna or Steam Room?
Operating Temperature
Is Continuous Steam Exposure Expected?
Is Regular Washdown Required?
Is Thermal Cycling Expected?
Is Waterproofing Required Behind Wall / Ceiling Finishes?
Is Vapour Control Required?
Is Insulation Present / Planned?
ℹ Sauna & steam conditions Sauna and steam-room environments experience elevated temperature, humidity and repeated thermal cycling. Waterproofing and detailing must be compatible with these conditions and with the wall, ceiling and insulation build-up.
G

Drainage, Joints & Penetrations

Are Floor Drains Provided?
Are Overflow Drains / Channels Provided?
Is Proper Slope Available?
Are There Pool Inlets / Outlets?
Are There Pipe Penetrations?
Are There Light / Electrical Penetrations?
Are There Expansion / Movement Joints?
Are There Construction Joints?
Are Pool Steps / Benches Present?
Is an Overflow Gutter Present?
ℹ Critical detailing areas Drains, pipe penetrations, joints, corners, steps, benches and overflow channels are common areas requiring extra waterproofing detailing. These locations are treated as part of the continuous waterproofing system, not simply coated over.
H

Waterproofing System & Finish

What Type of Waterproofing Are You Looking For?
Required Waterproofing Location
Required Flexibility
Is Crack-Bridging Performance Required?
Is Reinforcement Mesh / Fabric Required?
Number of Waterproofing Coats
Required Final Finish
Tile / Finish Adhesive Specification Available?
ℹ System compatibility The waterproofing system, tile adhesive, grout and final finish should be considered together. Compatibility is particularly important in continuously immersed areas such as swimming pools.
I

Site Access & Working Conditions

Is the Waterproofing Area Easily Accessible?
Is Material Lifting Required?
Is Electricity Available?
Is Water Available?
Is Adequate Ventilation Available?
Can the Area Be Kept Dry During Application?
Can the Area Be Isolated During Waterproofing?
Is the Building / Facility Occupied?
Are There Any Site Restrictions?
J

Testing, Protection & Handover

Is Water Testing Required?
Is Pond Testing Possible?
How Long Can the Area Remain Without Final Finish?
Who Will Carry Out the Final Tiling / Finish?
Is Protection of Waterproofing Required Before Tiling?
Is a Site Inspection Required?
Preferred Site Inspection Date / Time
Additional Information / Requirements
✓

Save This Entry

OPS

Operational Procedure

01
Site Assessment & Waterproofing Review

We begin by assessing the pool, sauna or steam-room area, including the structure, dimensions, substrate, water exposure, temperature conditions, drainage and final finish.

Project assessment Substrate and exposure review
02
Substrate Inspection & Preparation

The concrete, plaster or other substrate is inspected for cracks, honeycombing, weak areas, contamination and other defects. Unsuitable or damaged material is removed and the surface is prepared to receive the waterproofing system.

Surface preparation Repair where required
03
Crack & Structural Detail Treatment

Cracks, construction joints, movement joints and other areas of potential movement are treated using suitable compatible materials before the main waterproofing application.

Crack treatment Joint treatment
04
Pipe, Drain & Penetration Treatment

Pool inlets, outlets, drains, overflow channels, electrical penetrations, pipe penetrations and other service openings are carefully detailed to maintain continuity of the waterproofing system.

Drains Pipe penetrations Service details
05
Corners, Steps & Special Details

Internal corners, external corners, steps, benches, pool edges and other changes in direction are treated to ensure continuous waterproofing across the complete surface.

Steps Benches Corners
06
Primer / Base Preparation

Where required by the selected system, a compatible primer or base treatment is applied to the prepared substrate before the waterproofing layers are installed.

As per system specification
07
Waterproofing Application

The selected waterproofing system is applied uniformly to the prepared substrate at the specified coverage and thickness. Multiple coats are applied where required, with appropriate curing or drying time between coats.

System and thickness as specified
08
Reinforcement & Detail Reinforcement

Where specified, reinforcement mesh, fabric or additional waterproofing layers are incorporated at cracks, joints, corners, penetrations and other areas requiring additional protection.

As specified
09
Sauna / Steam Room Waterproofing

For sauna and steam-room applications, the waterproofing system is continued across the specified floor and wall areas, with particular attention to corners, penetrations, floor-to-wall junctions and areas exposed to repeated heat and moisture.

Thermal and moisture exposure
10
Waterproofing Continuity Inspection

The completed waterproofing is inspected to verify continuous coverage, adequate detailing and treatment of all identified penetrations, joints, corners and drainage points.

Coverage Detail inspection
11
Water Testing / Pond Testing

Where applicable, the waterproofed pool or wet area is subjected to an agreed water or ponding test after the required curing period. The area is inspected for leakage or water loss before the final finish proceeds.

Where applicable
12
Protection & Final Finish Preparation

After successful completion of the waterproofing and testing requirements, the waterproofed surface is protected from damage during subsequent construction. The surface is prepared for the specified tile, mosaic, stone, screed or other final finish.

Protection before finishing
13
Final Inspection & Handover

The completed waterproofing installation is inspected and photo-documented. The waterproofed area is handed over after the required curing, testing and protection stages have been completed.

Final inspection Photo documentation Handover
CLN

Cleaning & Equipment

Application Tools

Brushes, rollers, and trowels are cleaned immediately after use — waterproofing coatings harden fast and ruin tools left uncleaned.

Mixing Equipment

Drum mixers and paddles are rinsed between batches, especially when switching between different waterproofing systems.

Testing Equipment

Water/pond testing setup (hoses, plugs, gauges) is drained and stored dry after each test.

Site Cleanup

Excess material, packaging, and debris from hacking/repair work is cleared before handover, leaving the site in a workable condition.

© 2026 INDIGOiND Construction Solutions Pvt. Ltd. · Kochi · Doha
← All assessment formsinfo@indigoin.in