INDIGOiND Construction Solutions
Home/Site assessment forms/Standard Waterproofing
Pre-job site assessment

Standard Waterproofing

Site Assessment Form · Operation/Procedure  |  Rev 1.0
⚠ Identify the water source & existing surface condition first  ·  For pools, saunas & steam rooms use the Swimming Pool / Sauna Waterproofing form instead
A

Project Basics

Project Name / Building Name
Project Location
Client / Company Name
Contact Person
Mobile / WhatsApp Number
Email ID
Type of Project
Is the Building New or Existing?
Expected Start Date
Work Shift
Is the Building Occupied?
B

Waterproofing Requirement

Where Is Waterproofing Required?Select all that apply
What Is the Main Requirement?Select all that apply
Is This a New Waterproofing System or Existing System Repair?
ℹ New vs re-waterproofing New construction generally allows the waterproofing system to be incorporated into the complete floor and wall build-up. Existing areas may require removal of finishes, repair of the substrate and investigation of the source of leakage before waterproofing begins.
C

Area & Quantity

Approximate Waterproofing Area
Number of Toilets / Bathrooms
Number of Kitchens
Number of Balconies
Number of Terraces / Roof Areas
Approximate Terrace / Roof Area
Is Vertical Waterproofing Required?
D

Existing Surface & Substrate

What Is the Existing Surface?
Condition of Existing Surface
Are Tiles / Existing Finishes Present?
Are Existing Tiles to Be Removed?
Is Existing Waterproofing Present?
Is Removal / Hacking of Existing Waterproofing Required?
Are There Visible Cracks?
Are There Damaged / Hollow Areas?
Is the Surface Uneven?
ℹ Surface preparation A waterproofing system performs only as well as the surface beneath it. Loose concrete, damaged screed, hollow areas, cracks, dust, contamination and unsuitable existing coatings may need to be repaired or removed before waterproofing.
E

Water Leakage & Moisture

Is There an Existing Water Leakage?
Where Is the Leakage Occurring?
When Does Leakage Occur?
What Is the Suspected Water Source?
Is Water Currently Entering the Building?
Is There Dampness / Moisture on the Surface?
Is There Standing / Ponding Water?
Has Waterproofing Been Attempted Previously?
If Yes, What Material / System Was Used?
Was the Previous Waterproofing Successful?
F

Drainage, Slope & Detail Requirements

Is Proper Slope Available for Drainage?
Are Floor Drains Available?
Condition of Floor Drains
Are There Pipe Penetrations?
Are There Multiple Pipe Penetrations?
Are There Floor-to-Wall Junctions Requiring Treatment?
Are There Construction / Movement Joints?
Are There Door Thresholds Requiring Waterproofing Detail?
Is Waterproofing Required Behind Wall Tiles?
Is Waterproofing Required Up the Wall?
Approximate Waterproofing Height
ℹ Wet-area detailing Bathrooms, kitchens and similar wet areas require particular attention at floor-to-wall junctions, pipe penetrations, drains, corners and door thresholds. Waterproofing may also need to continue up the wall depending on the area and final finish.
G

Waterproofing System

What Type of Waterproofing Are You Looking For?
Is the Area Exposed to Direct Sunlight?
Is the Area Exposed to Rain?
Will the Waterproofing Be Covered?
Is the Waterproofing on the Positive or Negative Side?
Is Hydrostatic Pressure Expected?
Is Crack-Bridging / Flexible Waterproofing Required?
ℹ System selection The appropriate waterproofing system depends on whether the area is internal or external, exposed or covered, subject to movement or hydrostatic pressure, and what finish will be installed over it. Where the system hasn't been specified, IndigoInd can recommend a suitable system based on site conditions.
H

Special Requirements

Is PU Injection Required?
Are Active Cracks Present?
Are Construction Joints Present?
Are Pipe Penetrations Requiring Special Treatment?
Is a Protective Screed Required?
Is Reinforcement Mesh / Fabric Required?
Is Waterproofing Required Below Tiles?
Is Waterproofing Required Above the Ceiling / Below Slab?
Is the Area Subject to Regular Washdown?
Is Chemical Exposure Expected?
I

Site Access & Working Conditions

Is the Waterproofing Area Easily Accessible?
Is Material Lifting Required?
Is Electricity Available?
Is Water Available?
Can the Area Be Kept Dry During Application?
Can the Area Be Isolated During the Work?
Are There Any Site Restrictions?
Is the Area Occupied During Waterproofing?
J

Finish, Protection & Handover

What Finish Will Be Installed After Waterproofing?
Who Will Install the Final Finish?
Is Protection of the Waterproofing Required?
Is Water / Pond Testing Required?
How Long Can the Area Remain Without Final Finish?
K

Photos, Drawings & Project Information

⚠ This form can't accept file uploads. Send photos, close-ups, and drawings separately via WhatsApp or email — use the checklist below to confirm what's been sent.
Photos & Drawings NotesWhat's been sent via WhatsApp/email
BOQ / Specification Available?
Consultant Specification Available?
Approved Waterproofing Brand / System Specified?
This Enquiry Is For
Additional Information / Specific Requirement
✓

Save This Entry

OPS

Operational Procedure

01
Site Assessment & Waterproofing Requirement Identification

We begin by assessing the area, identifying the waterproofing requirement and reviewing the existing surface, water exposure, intended finish and site conditions.

Project assessment Requirement identification
02
Substrate Inspection & Surface Preparation

The substrate is inspected for cracks, damaged areas, loose material, contamination and existing coatings or waterproofing. Unsuitable material is removed and the surface is prepared to receive the selected waterproofing system.

Surface preparation Repair where required
03
Crack & Surface Repair

Cracks, damaged screed, honeycombing, hollow areas and other substrate defects are repaired using suitable compatible materials before waterproofing begins.

Crack treatment Surface repair
04
Drainage & Slope Preparation

The floor is checked to ensure that water can drain effectively toward the designated outlets. Ponding areas, defective drainage points and relevant slope issues are addressed where included in the agreed scope.

Drainage assessment
05
Pipe, Drain & Junction Treatment

Floor drains, pipe penetrations, floor-to-wall junctions, corners, thresholds and other vulnerable details are treated to maintain continuity of the waterproofing system.

Drains Pipe penetrations Corners
06
Primer / Base Preparation

Where required, a compatible primer or base treatment is applied to the prepared substrate before the main waterproofing system.

As per system specification
07
Waterproofing Application

The selected waterproofing system is applied uniformly at the specified coverage, thickness and number of coats. Each layer is allowed the required drying or curing time before the next stage.

System and thickness as specified
08
Reinforcement & Detail Treatment

Where required, reinforcement mesh, fabric or additional waterproofing layers are incorporated at cracks, corners, joints, penetrations and other vulnerable areas.

Where specified
09
Wall & Wet-Area Waterproofing

Where specified, waterproofing is continued vertically onto walls and other wet-area surfaces to provide continuous protection behind the final finish.

Floor / Wall / Full wet-area treatment
10
Water Testing & Inspection

Where applicable, the completed waterproofing is subjected to an appropriate water or ponding test after the required curing period. The waterproofed area is inspected before the final finish is installed.

Where applicable
11
Protection & Final Finish Preparation

The completed waterproofing is protected from damage during subsequent construction. The surface is prepared for the specified tile, screed, concrete, soil or other final finish.

Protection before finishing
12
Final Inspection & Handover

The completed waterproofing is inspected for continuity, detailing and visible defects. The finished work is photo-documented and handed over after the required curing, testing and protection stages are completed.

Final inspection Photo documentation Handover
© 2026 INDIGOiND Construction Solutions Pvt. Ltd. · Kochi · Doha
← All assessment formsinfo@indigoin.in